Home > Informix Cannot > Informix Cannot Find Message File

Informix Cannot Find Message File

RUIZ GARZON -- Monday, 26 December 2005, at 2:38 p.m. For a backup, the database server should be in online or quiescent mode. An error might exist in the configuration of the database software. Already a member? http://pgexch.com/informix-cannot/informix-cannot-find-message-file-check-informixdir-and-dblang.html

Verify that the data exists. 43011 Updates to table_name primary key are not allowed. Add the correct service name if it is not present or restart your computer. Contact your system administrator if you need help setting the environment variable. 2005 Database database-name not found or not correct format. If not, note all circumstances and contact IBM Technical Support. -53 Software caused connection abort. http://www.ibm.com/support/docview.wss?uid=swg21567290

The database server did not find any more data. Progress, Telerik, and certain product names used herein are trademarks or registered trademarks of Progress Software Corporation and/or one of its subsidiaries or affiliates in the U.S. Note: It is suggested to install tools in a directory other than the directory where the server is installed.

The INFORMIXDIR environment variable is probably not set properly. If the current operation requires the use of a text file (such as the input file to LOAD or to a PRINT FILE statement in a report), retry the operation later. The database server could not open the next audit file because the call to aio_fopen() failed. Thanks in advance for your comments.

Check with your system administrator to ensure that the system is working properly. 32727 Feature was never checked out. Fix the ONCONFIG file so that the parameter is 0/1. 38095 string is invalid setting for ADTMODE. If this internal error recurs, note all circumstances and contact IBM Technical Support. 35586 General Table Manager: Table is locked. https://groups.google.com/d/topic/comp.databases.informix/KHEHBjqyDFI Either IBM has not certified the XBSA shared library that the Storage Management Vendor provides, or an error occurred during installation of ON-Bar.

This message provides information to the user. This error indicates that an internal error occurred during sending or receiving of the message. Syntax Error : Stored Procedure 3. An operating-system error code with the meaning shown was unexpectedly returned to the database server.

The account under which you are logged on might not be a member of the informix-admin group. http://members.iiug.org/forums/ids/index.cgi/noframes/read/6151 Verify that the /etc/hosts file contains the requested host-name entry. 25530 The sqlexecd daemon cannot bind to the required port address. oninit -i: "Cannot find message file"- Error Messages 4. Look for other operating-system error messages that might give more information. -27 File too large.

Progress Software Corporation makes no explicit or implied claims to the validity of this information. http://pgexch.com/informix-cannot/informix-cannot-write-blob.html Contact your database system administrator. 43018 Must be user root or informix. Reduce the number of VPCLASS lines and restart oninit. 19569 oninit: VPCLASS VPCLASS_name bad affinity specification. An operating-system error code with the meaning shown was unexpectedly returned to the database server.

Lester Knutsen (IBM Champion) writes about database back up safety using "archecker"... Check that you specified the appropriate pathname when you set the INFORMIXDIR and DBLANG environment variables. Reasons such as off-topic, duplicates, flames, illegal, vulgar, or students posting their homework. navigate here If the segments added by engine are more than 3, you might find yourself in problems, so better increase the value of SHMVIRTSIZE.

Getting the following message: "Cannot find message file.Check INFORMIXDIR and DBLANG." when using 'oninit' to start things up. Use this SQLCODE value to determine when a statement reaches the end of the data. If the error recurs, note all circumstances and contact IBM Technical Support. 32726 Cannot allocate dynamic memory.

The affinity specification for the VPCLASS line is incorrect.

This error usually occurs when all the software components are not built with the same encryption code. Look for other operating-system error messages that might give more information. An operating-system error code with the meaning shown was unexpectedly returned to the database server. Correct the problem and clear the alter mode manually through cdr command line utility. 19820 Informix OUTER JOIN and ANSI JOIN in the same query block.

An operating-system error code with the meaning shown was unexpectedly returned to the database server. Attempt to build a WHERE clause for the specified query failed. Enter your request again. http://pgexch.com/informix-cannot/informix-cannot-locate-service-tcp.html That error might include an incorrect address in the chunk-device or tape-device parameters that were given to the database server.

Ask your system administrator to add your user name to the informix-admin group. 43039 Version version_number of the XBSA shared library is not compatible with version version_number of ON-Bar. Look for other operating-system error messages that might give more information, such as the device on which the error occurred. For details, see your Administrator's Guide. 43015 Unable to set INFORMIXSHMBASE. An operating-system error code with the meaning shown was unexpectedly returned to the database server.

If the error recurs, note all circumstances and contact IBM Technical Support. -6 No such device or address.